The application of GSM burglar alarms in the monitoring of the room environment and theft prevention With the advent of the IT era, computer rooms (computer centers, equipment rooms, wiring closets, base stations, etc.) have become an important part of all units, computer rooms (computer centers, equipment, The environmental equipment (power distribution, UPS, air conditioning, temperature and humidity, water leakage, fire protection, security, etc.) must provide a normal operating environment; otherwise, it will affect the operation of the entire system. Severe accidents that cannot be dealt with in time can have serious consequences. Therefore, at present, many computer room managements have to use 24-hour personnel on duty to regularly inspect equipment in the equipment room. This not only increases the burden on management personnel, but often does not eliminate faults in time. In particular, at present, there is a general lack of professional management personnel for equipment room equipment. It is very important for computer room automation management of the computer room.
XN-MONITOR room monitoring and management system can realize unified monitoring and management of equipment room and environment of the equipment room, monitor the status and parameters of various equipments, have expert diagnosis function, guide on-duty personnel to solve problems timely and accurately, and improve the reliability of system operation to ensure The information system operates safely.
Applicable areas: government agencies, customs, electricity, radio and television systems, education systems, transportation, banking, taxation, telecommunications, and intelligent buildings.
1, the computer's operating status remote monitoring query computer's current status SMS monitoring alarm system through the serial port and the computer connection, real-time communication with the monitoring software, regularly sent to the administrator phone computer normal operation SMS report, the administrator can also send SMS command query The current state of the computer crashes or powers off the remote alarm. When the computer crashes or loses power, the short message monitoring alarm host disconnects from the computer, and immediately sends an alarm SMS message to the administrator's mobile phone to remotely restart the computer SMS monitoring. The alarm host provides Switch signal output terminal, the user can send a short message command to let the terminal output the pulse signal, connect the terminal to the RESET key of the computer. Once the computer crashes, the administrator can send a signal output command to restart the computer.
2, UPS monitoring connection: alarm controller through the data line and the UPS dry contact connected by the UPS power SMS alarm: When the UPS occurs the following problems, it will send text messages to the police: 1 abnormal power, UPS to the battery; 2 UPS low battery Work, the battery will run out; 3 UPS communication lost or cut off the load power; 4 UPS equipment needs to replace the new battery; 5 UPS equipment starts to bypass work; 6 UPS unclear failure SMS control: send a text message to close or open the UPS (can be Select function, not recommended) Status query: administrator can send SMS to check the current status of UPS
3. Network monitoring connection mode: Alarm controller connects to any terminal or server on the LAN through the serial port. SMS alarm: The alarm monitors the server on the network in real time. When the server is abnormal (such as crash), it will send a short message for alarm message control: Send a text message to close the server status query: The administrator can send text messages to query the server's current status
4, temperature and humidity monitoring equipped with temperature and humidity sensor; when the temperature value exceeds the set range, text message alarm status query: administrator can send text messages to query the temperature and humidity of the engine room
5, smoke monitoring with smoke sensor; when the smoke concentration exceeds a certain range, send text messages to the police
6, illegal intrusion monitoring equipped with magnetic sensors; when the doors and windows are opened illegally, send text messages to the alarm equipped with infrared detectors: when someone is illegal to enter, send text messages to the alarm without the staff's duty time automatically open, there is staff time automatically closed .
7, the total control room management platform When the need for centralized monitoring of each room, you need SMS alarm management platform; this way, the above exception occurs in the engine room, the management platform will receive a warning message