450/750V PVC/PVC Sheathed Copper Wire LSZH Shielded Control Cable

Model NO.: LSZH Shielded Control Cable
Range of Application: Flame Retardant
Certification: ISO9001, CE, CCC, RoHS
Insulation: PVC
Core: Single/Multi-Cores
Standard: IEC/NFC33-209
Quality Guarantee: 10 Years
Sheath Color: Black
Mark: Laser Type
Manufacture: Yes
Sample: Yes
Cable Parts: Yes
Conductor: Copper/Al Core
Trademark: Hongda
Transport Package: Wooden Plate
Specification: 1.5-630sqmm
Origin: China, Henan
HS Code: 8544492100
Model NO.: LSZH Shielded Control Cable
Range of Application: Flame Retardant
Certification: ISO9001, CE, CCC, RoHS
Insulation: PVC
Core: Single/Multi-Cores
Standard: IEC/NFC33-209
Quality Guarantee: 10 Years
Sheath Color: Black
Mark: Laser Type
Manufacture: Yes
Sample: Yes
Cable Parts: Yes
Conductor: Copper/Al Core
Trademark: Hongda
Transport Package: Wooden Plate
Specification: 1.5-630sqmm
Origin: China, Henan
HS Code: 8544492100
 

The "Low Smoke" element of LSZH cables

According to Part B of The Building Regulations, a leading planning and building regulations resource for England and Wales:

"The primary danger associated with fire in its early stages is not flame but the smoke and noxious gases produced by the fire. They cause most of the casualties and may also obscure the way to escape routes and exits. Measures designed to provide safe means of escape must therefore provide appropriate arrangements to limit the rapid spread of smoke and fumes."

Burning PVC has been found in tests to reduce visibility in the surrounding area by as much as 50% within 10 minutes. After 30 minutes, visibility can be reduced by as 90% making it unnecessarily challenging to escape the area.

By comparison, BS EN 61034 specifies a smoke density test, performed inside a chamber 3m x 3m x 3m. The test is often referred to as the 3 metre cube test. By monitoring the transmittance reduction of a white light beam running from one side of the chamber to the other at a set height, the build-up of smoke inside the chamber can be measured. For a cable to be classified as low smoke it will often have a minimum light transmittance of 60%. 

The "Zero Halogen" element of LSZH cables

Burning PVC and other cable compounds produce a number of chemicals, including hydrogen chloride (HCl), which is highly toxic. Furthermore, when mixed with water, HCl forms hydrochloric acid; a substance which is both toxic and corrosive. In the case of PVC, as much as 30% of the emissions can be HCl.

BS EN 60754 stipulates that emissions of HCl by LSZH cables must not exceed 0.5%.

 

LSZH vs LSF cables

Whilst there is a common misconception that low smoke and fume (LSF) cables and LSZH cables are the same, this is not the case and any confusion between the two could be life-threatening in the event of a fire.

Unlike LSZH cables, LSF cables are manufactured using PVC compounds. If they are labelled as low smoke and fume cables it is due to the manufacturer modifying the compound with various additive in order to reduce (not eliminate) smoke and HCl emissions. However, where low smoke zero halogen cables are subject to strict standards, there are no standards governing LSF cables. As a result, LSF cables have been found to emit HCl levels in excess of 20% when burning.

LSZH cable selection

There have been many developments in relation to LSZH cable standards and legislation since the Kings Cross Station fire of November 1987 which resulted in 31 fatalities. Findings from the official investigation outlined that the majority of these deaths were as a result of toxic fumes, pointing to the vast quantities of PVC present in the building, much of which was in PVC cables. PVC cables were subsequently banned by London Underground.


450/750V PVC/PVC Sheathed Copper Wire LSZH Shielded Control Cable

 

450/750V PVC/PVC Sheathed Copper Wire LSZH Shielded Control Cable
 

Size: 0.5-630mm2 , BV BVV BVR RV RVV,RVS

Length: 100M 200M 300M 500M/roll, Can make as your request.
 

Type Cross Section(mm2) Conductor Size(No. of Cores/Diameter) Rated Voltage Nominal Insulation Thickness(mm) Reference Weight(kg/km) Application
Solid Type 0.5 1/0.80

300/500V

450/750V

0.6 8.0 Solid, Hard,Suitable for fixed installation
0.75 1/0.97 0.6 11.4
1 1/1.13 0.6 15.2
1.5 1/1.38 0.7 21
2.5 1/1.78 0.7 32
4 1/2.25 0.8 47
6 1/2.76 0.8 67
Stranded Type 1.5 7/0.52 0.7 22 Stranded, Flexible house wiring, Suitable for indoor applicant.
2.5 7/0.68 0.7 35
2.5 19/0.40 0.8 34
4 7/0.85 0.8 50
4 19/0.52 0.8 51
6 7/1.04 0.8 71
6 19/0.64 0.8 72
10 7/1.35 1.0 118
10 49/0.52 1.0 127
16 7/1.70 1.0 177
16 49/0.64 1.0 184
Flexible Type 1.5 30/0.25 0.7 22 Ultra Flexible, Soft Conductor, Suitable for small power equipment instrument.
2.5 49/0.25 0.8 34
4 56/0.30 0.8 49
6 84/0.30 0.8 70
10 77/0.40 1.0 117
16 119/0.40 1.0 168
25 189/0.40 1.2 265
...      

  The cable can be of flame retardance, fire resistance, environment friendly or other property. OEM Available.


Packaging&Delivery
450/750V PVC/PVC Sheathed Copper Wire LSZH Shielded Control Cable450/750V PVC/PVC Sheathed Copper Wire LSZH Shielded Control Cable

 

Packaging Details: Packing Length:100m/roll, 200m/roll, 305m/roll, 500m/roll
Delivery Time:Normally within 10 days (detailly depend on the order quantity)

 Contact us

Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software. 
 Tel :+86 15039132763  

 

The "Low Smoke" element of LSZH cables

According to Part B of The Building Regulations, a leading planning and building regulations resource for England and Wales:

"The primary danger associated with fire in its early stages is not flame but the smoke and noxious gases produced by the fire. They cause most of the casualties and may also obscure the way to escape routes and exits. Measures designed to provide safe means of escape must therefore provide appropriate arrangements to limit the rapid spread of smoke and fumes."

Burning PVC has been found in tests to reduce visibility in the surrounding area by as much as 50% within 10 minutes. After 30 minutes, visibility can be reduced by as 90% making it unnecessarily challenging to escape the area.

By comparison, BS EN 61034 specifies a smoke density test, performed inside a chamber 3m x 3m x 3m. The test is often referred to as the 3 metre cube test. By monitoring the transmittance reduction of a white light beam running from one side of the chamber to the other at a set height, the build-up of smoke inside the chamber can be measured. For a cable to be classified as low smoke it will often have a minimum light transmittance of 60%. 

The "Zero Halogen" element of LSZH cables

Burning PVC and other cable compounds produce a number of chemicals, including hydrogen chloride (HCl), which is highly toxic. Furthermore, when mixed with water, HCl forms hydrochloric acid; a substance which is both toxic and corrosive. In the case of PVC, as much as 30% of the emissions can be HCl.

BS EN 60754 stipulates that emissions of HCl by LSZH cables must not exceed 0.5%.

 

LSZH vs LSF cables

Whilst there is a common misconception that low smoke and fume (LSF) cables and LSZH cables are the same, this is not the case and any confusion between the two could be life-threatening in the event of a fire.

Unlike LSZH cables, LSF cables are manufactured using PVC compounds. If they are labelled as low smoke and fume cables it is due to the manufacturer modifying the compound with various additive in order to reduce (not eliminate) smoke and HCl emissions. However, where low smoke zero halogen cables are subject to strict standards, there are no standards governing LSF cables. As a result, LSF cables have been found to emit HCl levels in excess of 20% when burning.

LSZH cable selection

There have been many developments in relation to LSZH cable standards and legislation since the Kings Cross Station fire of November 1987 which resulted in 31 fatalities. Findings from the official investigation outlined that the majority of these deaths were as a result of toxic fumes, pointing to the vast quantities of PVC present in the building, much of which was in PVC cables. PVC cables were subsequently banned by London Underground.


450/750V PVC/PVC Sheathed Copper Wire LSZH Shielded Control Cable

 

450/750V PVC/PVC Sheathed Copper Wire LSZH Shielded Control Cable
 

Size: 0.5-630mm2 , BV BVV BVR RV RVV,RVS

Length: 100M 200M 300M 500M/roll, Can make as your request.
 

Type Cross Section(mm2) Conductor Size(No. of Cores/Diameter) Rated Voltage Nominal Insulation Thickness(mm) Reference Weight(kg/km) Application
Solid Type 0.5 1/0.80

300/500V

450/750V

0.6 8.0 Solid, Hard,Suitable for fixed installation
0.75 1/0.97 0.6 11.4
1 1/1.13 0.6 15.2
1.5 1/1.38 0.7 21
2.5 1/1.78 0.7 32
4 1/2.25 0.8 47
6 1/2.76 0.8 67
Stranded Type 1.5 7/0.52 0.7 22 Stranded, Flexible house wiring, Suitable for indoor applicant.
2.5 7/0.68 0.7 35
2.5 19/0.40 0.8 34
4 7/0.85 0.8 50
4 19/0.52 0.8 51
6 7/1.04 0.8 71
6 19/0.64 0.8 72
10 7/1.35 1.0 118
10 49/0.52 1.0 127
16 7/1.70 1.0 177
16 49/0.64 1.0 184
Flexible Type 1.5 30/0.25 0.7 22 Ultra Flexible, Soft Conductor, Suitable for small power equipment instrument.
2.5 49/0.25 0.8 34
4 56/0.30 0.8 49
6 84/0.30 0.8 70
10 77/0.40 1.0 117
16 119/0.40 1.0 168
25 189/0.40 1.2 265
...      

  The cable can be of flame retardance, fire resistance, environment friendly or other property. OEM Available.


Packaging&Delivery
450/750V PVC/PVC Sheathed Copper Wire LSZH Shielded Control Cable450/750V PVC/PVC Sheathed Copper Wire LSZH Shielded Control Cable

 

Packaging Details: Packing Length:100m/roll, 200m/roll, 305m/roll, 500m/roll
Delivery Time:Normally within 10 days (detailly depend on the order quantity)

 Contact us

Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software. 
 Tel :+86 15039132763  

Data cable

Dongguan Guancheng Precision Plastic Manufacturing Co., Ltd. , https://www.dpowerchargers.com

This entry was posted in on