Storage conditions: 2-8
°C
Sample processing and requirements
1. Serum: The blood is naturally coagulated for 10-20 minutes at room temperature and centrifuged for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if precipitation occurs during storage, it should be centrifuged again.
2. Plasma: EDTA or sodium citrate should be selected as an anticoagulant according to the requirements of the specimen. After mixing for 10-20 minutes, centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again.
3. Urine: Collect with a sterile tube and centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again. The chest and ascites and cerebrospinal fluid are referred to.
4. Cell culture supernatant: When detecting secreted components, collect them in a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When the components in the cells were detected, the cell suspension was diluted with PBS (pH 7.2-7.4), and the cell concentration reached about 1 million/ml. By repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.
5. Tissue specimen: After cutting the specimen, weigh the weight. Add a certain amount of PBS, pH 7.4. It was quickly frozen and stored in liquid nitrogen for use. The specimen still maintains a temperature of 2-8 ° C after melting. A certain amount of PBS (pH 7.4) was added, and the specimen was homogenized by hand or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. One part of the package is to be tested, and the rest is frozen for use.
6. The specimens should be extracted as soon as possible after collection, and the extraction should be carried out according to the relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately,
Put the specimen in
-20
°C save, but
should
Avoid repeated freezing and thawing
.
7.
Cannot detect samples containing NaN3
, NaRP3 inhibits horseradish peroxidase (HRP) activity.
Steps
1.
Dilution and loading of standard products: 10 holes of standard holes are set on the enzyme label coating plate, and standard 100 is added to the first and second holes respectively.
μ
l, then add standard dilution 50 in the first and second holes
μ
l, mix; then take 100 from each of the first hole and the second hole
μ
l are added to the third hole and the fourth hole respectively, and then the standard dilution 50 is added to the third and fourth holes respectively.
μ
l, mix; then take 50 in each of the third hole and the fourth hole
μ
l Discard, then take 50 each
μ
l Add to the fifth and sixth holes respectively, then add 50ul of the standard dilution solution in the fifth and sixth holes, and mix; after mixing, take 50 from each of the fifth and sixth holes.
μ
l Add to the seventh and eighth holes respectively, and add standard dilution 50 to the seventh and eighth holes respectively.
μ
l, after mixing, take 50 from the seventh and eighth holes respectively
μ
l Add to the ninth and tenth holes, and add the standard dilution 50 to the ninth and tenth holes respectively.
μ
l, after mixing, take 50 from each of the ninth and tenth holes
μ
l Discard. (The amount of each well after dilution is 50
μ
l, the concentration is 36
u
g/ml
,twenty four
u
g/ml
12
u
g/ml
,6
u
g/ml
, 3
u
g/ml
).
2.
Adding samples: set blank holes separately (the blank control wells are not added with samples and enzyme-labeled reagents, and the other steps are the same),
Sample hole to be tested
. Add sample dilution 40 to the sample well to be tested on the enzyme coated plate.
μ
l, then add the sample to be tested 10
μ
l (The final dilution of the sample is 5 times). Add the sample to the bottom of the well of the ELISA plate and try not to touch the hole wall.
lightly
Shake
Mix
.
3.
Incubation: Sealing the plate with a sealing film 37
°C incubation 3
0
minute
.
4.
Solution: 30 times concentrated washing solution was diluted 30 times with distilled water and set aside.
5.
Washing: Carefully remove the sealing film and discard the liquid.
Dry
Fill each well with the washing solution, let stand for 30 seconds, then discard it, repeat 5 times, and pat dry.
6.
Add enzyme: add 50ul of enzyme labeling reagent per well, except for blank holes
.
7.
Incubation: The operation is the same as 3.
8.
Washing: The operation is the same as 5.
9.
Color development: add A50ul of coloring agent to each well, then add coloring agent B50ul, gently shake and mix, 37
°C in the dark for 15 minutes.
10.
Termination: per hole plus termination
Liquid 50
Ul
, stop the reaction
(At this time, the blue turns yellow)
.
11.
Determination: zeroing with a blank hole,
4
50
The nm wavelength measures the pores sequentially
Absorbing light
Degree (OD value)
.
The measurement should be carried out within 15 minutes after the addition of the stop solution.
Precautions
1. The kit should be taken out from the refrigerated environment and should be used at room temperature for 15-30 minutes before use. If the enzyme label is unsealed after opening, the slats should be stored in a sealed bag.
2.
Concentrated washing solution
may
There will be
crystallization
Precipitation, warming in a water bath when diluting
, washing does not affect the results.
3. The sampler should be used for each step, and the accuracy should be corrected frequently to avoid test errors. It is best to control the loading time within 5 minutes. If the number of specimens is large, it is recommended to use a gun.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is larger than the OD value of the first hole of the standard well), please first dilute the sample dilution with a certain multiple (n times) before measuring.
Multiply by
Total dilution factor (
×n×5
).
5. The sealing film is for one-time use only to avoid cross-contamination.
6. Please keep the substrate away from light.
7. Strictly follow
Bovine serum albumin (BSA) enzyme-linked immunosorbent assay (ELISA) kit
Instruction manual
The operation is carried out, and the test results must be determined by the microplate reader reading.
8. All samples, washings and various wastes should be treated as infectious materials.
9. The different batch components of this reagent should not be mixed.
10. In the case of an English manual, the English manual shall prevail.
Bovine serum albumin (BSA) enzyme-linked immunosorbent assay kit
performance
1. The linear regression coefficient of the sample and the expected concentration correlation coefficient R value is 0.92 or more.
2. Within and between batches should be less than 9% and 15% respectively
Our Fiber Optic Splice Trays are made of ABS, light in weight and is RoHS compliant. It mainly is used for optical fiber storage and fiber optic fusion protection, easy to operate and simple to install and uninstall. The Fiber Splice Trays are stackable and can be mounted using two #6 screws; they can be used one on top of another to form a layer structure inside the fiber optic enclosures.
Usually fiber optic splice trays are used inside the Fiber Enclosures, optical fiber glass inside the fiber tray can be melt with any other strand optical fiber in the tray, thus different fiber optic cables can be melt connected directly via the tray, optical cable fiber can also be melted with the fiber optic pigtail end, and via pigtail it can connect out to other fiber optic equipment. The tray expands fiber splice capabilities as well as provides the splicing location for the fiber optic cables. we have ready stock of this series products for immediate shipment.
FO Splicing Cassette, Fiber Optic Splicing Trays, Optical Trays, Cassette for FO Splicing 12 core, Cassette for FO Splicing 24 core
NINGBO YULIANG TELECOM MUNICATIONS EQUIPMENT CO.,LTD. , https://www.yltelecom.com