How to improve the safety of LED design and greatly reduce power consumption

Thermal management is the most difficult, demanding and costly design part of new LED lamps . Failure to perform adequate thermal management will result in catastrophic consequences such as lighting failure or fire. However, thermal management of LED lights is the most complex, demanding and costly part of the overall design. This article will explore how to implement negative temperature coefficient (NTC) thermal management to maximize the safety of LED designs and significantly reduce power consumption.

Among traditional incandescent bulbs, the filament that is not in direct contact with anything is the only source of heat. For LED lights, the LED is the light source, and the heat dissipation of the LED is directly in contact with the LED bulb . This direct contact is governed by the way the LEDs are connected to the driver circuitry. In order to achieve heat dissipation, heat must be released from the LED and driver circuits or managed effectively, and this is the basic premise for keeping the LEDs working for a long time.

To understand the importance of thermal management, we might consider an application that replaces the installation of LED lights on general lighting sockets such as wall or ceiling lights, and uses wall switches to control the LEDs. Since the heat dissipation of most standard lamps, such as wall or ceiling lights, is primarily dependent on thermal convection or airflow, the heat dissipation of this application is less than ideal for LED lamps.

Failure to perform effective thermal management can result in catastrophic consequences such as frequent replacement of failed LED lights or building fires. The use of intelligent LED light control to monitor the temperature of the LED light is a relatively simple thermal management method, and because the LED light can reduce the power when the temperature rises, the safety will be greatly improved.

NTC thermal management

The basic principle of the NTC circuit is to improve the safety of the LED lamp and reduce the design complexity by monitoring the temperature of the LED lamp. As the temperature increases, the controller reduces lumens and thereby keeps the LEDs within safe levels. In other words, when the temperature rises, the lumen is reduced, and conversely, when the temperature drops, the lumen is increased.

We can detect the temperature change of the LED lamp by detecting the voltage on the NTC. The detected voltage is directly related to the temperature of the NTC, and the resistance of the NTC decreases as the temperature of the NTC and its peripheral circuits increases. There are two basic ways to determine temperature using NTC.

Method 1: Use NTC in a voltage divider circuit that enforces a known voltage in the system, and then measure the voltage on the NTC node. When the NTC temperature rises, the resistance decreases. A decrease in resistance will result in a change in the divider ratio. The voltage at the NTC node also drops as the temperature increases.

Method 2, forcing the known current to pass through the NTC and measuring the voltage on the NTC. When the NTC temperature rises, the resistance decreases. According to Ohm's law, the reduction in resistance will change the voltage on the NTC node. If the resistance is reduced and the current remains the same, the voltage on the NTC node will also drop.

In terms of improving operation and improving safety, the two methods of monitoring the temperature of the LED lamp are simple and straightforward to implement. Figure 1 is a schematic diagram of two methods of using an LED as a source of temperature rise.

Is the temperature too high or is the LED fault?

When the lumen output of the LED lamp drops, it is important to know whether the LED output is degraded due to an excessive temperature environment or because the LED has failed. We can use an indicator that shows the drop in lumens to determine the cause of the drop.

The lumen drop in the system shown in Figure 2 is indicated by a low power red LED. When the system is at maximum lumen output, the red LED turns off; when the LED temperature rises, the lumen output drops, and when the lumen output drops, the red LED turns on. As the lumen output continues to decrease, the intensity of the red LED will increase accordingly. When the lumen output drops to its lowest intensity, the red LED will turn on completely.

When the lumen output is at the lowest intensity and the temperature of the LED light is still high, the red LED indicator can also serve as an alarm for serious problems. In the alarm mode, the red LED will flash continuously with the white LEDs all off.

The block diagram of Figure 3 shows a generic LED driver and LED controller with an NTC and an alarm indicator. A common LED light contains an LED driver that is configured to provide a set current through the LED. The drive cannot reduce lumens based on temperature. The temperature monitoring provided by the drive can only be used for self-protection and is completely shut down at very high temperatures.

The LED controller has all the control functions of a common LED driver and enhances the intelligence level of other functions such as temperature monitoring, communication and dimming control. The blue part of the block diagram is the basic module and components of the LED controller. Components shown in red are not required for basic operation, but are shown for the NTC and alarm functions described herein.

When an ordinary LED is added to the NTC, the LED can be turned off in a controlled order when the temperature reaches a preset limit. The two red components (resistors and NTCs) on the right side of the LED controller are configured according to Method 1 described in the NTC Operation section. The controller provides a precise voltage to the resistive element. The voltage at the NTC node is measured by the controller to be converted to the corresponding system temperature.

The alarm mechanism allows the LED to indicate an increase in temperature and to the extent that it must be turned off to ensure safety. The two red components (resistors and LEDs) on the left side of the LED controller are the basic indicator LED configurations. The brightness of the LED is controlled by a PWM (Pulse Width Modulation) signal. The LED will increase the brightness when the PWM duty cycle is increased.

The above intelligent LED lamp displays alarm information in the manner of another LED indicator. LED alarms are just one of the many communication interfaces that smart LEDs can use. Interfaces such as PLC (Power Line Communication), DMX (Digital Multiplexing), and DALI (Digital Addressable Lighting Interface) are also available.

Lumen adjustment

The flow chart of Figure 4 shows a simple algorithm for monitoring the temperature of the LED lamp and adjusting the lumen size if the temperature reaches a certain safety margin. The "Power On Start - System Initialization" block at the top of the flowchart is the microcontroller initialization block. After the wall switch is turned on, the LED light is turned on, and the block will be configured with LED lights for basic operations such as lumen output and temperature detection.

Is the light turned on? The block detects if the light is off due to excessive temperature. This simple bitwise test will clarify if the light is on. If it is set to the lamp open position, the light is on. If it is not set to the light open position, the light is not turned on. When power is first applied, the light is turned on by default and the light is set.

The "alarm" control block controls the sequence of switches after the temperature is too high and the LEDs are turned off by the controller. The next "Is the light on?" block will start the detection sequence again. The only way to exit the alarm condition is to disconnect and power the wall switch again.

The next "Detect Temperature" block will detect the voltage at the NTC node. NTC usually changes nonlinearly with temperature, so the detected voltage can be compared according to the comparison table. This temperature will be used for the next two control blocks.

The "Safe Temperature" block is used to determine if the temperature of the LED light is within safe limits. When the temperature reaches the configured maximum, the system turns off the light. If the temperature is below the allowable maximum, the system will continue the temperature stability test.

The function of the "lights off" block is to turn off the light when the LED light temperature is in an unsafe range. Next is the "Do you want to turn on the light?" block and restart the test sequence again.

The "Temperature Change" block is used to determine if the temperature change since the last lumen adjustment cycle requires an increase or decrease in light output. The "temperature increase" block is used to determine if the temperature is rising or falling. Since the previous control block has measured that the temperature change since the last lumen adjustment cycle was large enough, there are only two options.

The "Maximum Lumens" block is used to determine if the LED light is set to the maximum lumen output. If the lumen output reaches the maximum value, re-enter the "Do you want to turn on the light?" block and restart the detection sequence.

When the previous control block detects that the lumen output has not reached the maximum value, the "Lumens rise, dimming indicator" block is triggered. The control block will increase the output by one level according to the configuration during the initialization block, and will also turn the indicator LED down one level to match the lumen increase to the indicator dimming, and then restart the detection sequence.

When the "temperature rise" block detects an increase in temperature, the "minimum lumen" block is triggered. If the lumens do not reach the preset minimum value, the flow leads to the "Reduce lumens, brighten the indicator" block. If the lumen output reaches the preset minimum value, re-enter the "Do you want to turn on the light?" block and restart the detection sequence.

The “Lower Lumen, Brighten Indicators” block will lower the output by one level depending on the configuration during the initialization block, and will also turn the indicator LED up one level to match the lumen reduction to the indicator increase, then restart Detection sequence.

The above flow chart shows the case where the LED light remains off during the input power cycle. A slight change in the flow provides a sequence of monitoring the temperature after the lamp is turned off and re-opening the LED when the temperature falls below the safe limit.

High Voltage Power Modules

The CCP1000 series high-voltage power supply module is a single-phase 220Vac input modular high-voltage power supply. The whole series adopts unified small and compact aluminum chassis with the designed output power at 1KW, and the output voltage levels at 5KV / 10KV / 20KV / 30KV / 40KV / 50KV for selection.


Top View Of Ccp1000 Modular Hvps


Unlike common high voltage power modules that have a fixed output or only a limited range of voltage adjusting, the CCP1000 series adopts resonant inverter with PWM control. The output voltage and current of the high-voltage power module can be continuously adjusted from approximately 0 to the rated value, that is, a constant-voltage and constant-current type modular high-voltage power supply. Small potentiometers installed on the exposed circuit board on one side of the chassis can be adjusted by electric screwdriver to adjust the output voltage and current.
The HV power module is also equipped with a DB9 interface to facilitate the bus control of embedded installation equipment. Customers can apply 0-10V signals and dry contact signals to the interface according to our interface definition to achieve comprehensive control and monitoring functions on the power supply, like high voltage start / stop, output setting and reading.

The CCP1000 high voltage power modules are equipped with complete protection functions, which can deal with sparking, short-circuit, and overload conditions. With the discharge protection circuit recommended by iDealTek-Electronics, the high-voltage module can also cope with conventional capacitor charging and discharging conditions.

At present, the high voltage power modules are mainly used in air or oil fume purification, capacitor charging and other application fields that require a high-voltage power module that can be embedded installation.

High Voltage Module,High Voltage Power Module,High Voltage Booster Module,High Voltage Power Supply Module

Yangzhou IdealTek Electronics Co., Ltd. , https://www.idealtekpower.com

This entry was posted in on