LSY-7
Pipe scriber
one,
Pipe scriber
Product introduction:
Longitudinal retraction rate is an important indicator of the performance of plastic pipe products. It reflects the stability of plastic pipe products in the longitudinal plasticity of the pipe under thermal influence. Its measurement is of great significance to improve the ability of the product to withstand changes in temperature, sunlight and other heat sources, and to increase the life of the product. However, due to the diversity of methods for determining the longitudinal retraction rate, we often affect the accuracy of the detection due to improper operation or inadvertent attention.
two,
Pipe scriber
Scope of application:
in accordance with"
GBT 6671-2001
Thermoplastic pipe
Determination of longitudinal retraction rate" Determination of longitudinal retraction rate of plastic pipes.
three,
Pipe scriber
Instructions:
Place the standard sample of the line to be drawn on the two rollers and adjust the distance between the two brushes.
100mm
One of the brushes is at a distance from one end of the tube
10mm
, then turn the handwheel to draw an equidistance on the surface of the specimen
100mm
Two closed circumference lines
(
This length is the distance between the two lines before the experiment.
L0)
. Put the pretreated sample into the oven and heat it up according to the standard requirements, then cool and test the distance between the two lines of the pipe.
Ll
four,
Pipe scriber
Test result processing:
Longitudinal retraction rate
T=
_
L0-L
_
/ L0×100
Description: We draw two distances for each sample
100mm
Circumscribe the line and make it a line at least from either end of the specimen
10mm
. After the line is drawn, we should measure it again and use the measurement result as the original gauge length. Set the oven to the required
150
°C
When the oven reaches the specified temperature, we put the prepared sample. Measure again and use the measurement result as the original gauge length. Set the oven to the required
150
°C
When the oven reaches the specified temperature, we put the prepared sample. It should be noted here that when we put the sample, the oven should be
15min
Within the range, it will rise back to the set temperature. Therefore, we should not put too much sample into the sample, it should be within the range that the oven can withstand, and the action should be slightly faster, so that the temperature inside the oven is not too low. There are two methods for placing the sample here: the first suspension sample, the test is suspended in the oven, the suspension point should be at the farthest end of the line, and the sample should not touch the bottom and wall of the oven. For the second flat sample, the sample should be placed on a flat plate with a layer of talc and placed in an oven. Here we hang the two sets of samples in an oven for heating, and the other two are placed in an oven for heating. Turn off the oven when the oven temperature rises back to
150
°C
Time begins to remember. Placed here as required
60
minute.
60
After a minute, we took the sample out of the oven, placed the two sets of suspended samples flat on a smooth wooden countertop, and placed one on a smooth granite countertop. The other two groups are also placed separately. Wait for the sample to cool completely (
23±2
)
°C
When we measure the maximum or minimum distance between the marking lines, here we should make multiple measurements, choose
Li
The value that makes it the largest relative to the original gauge length is then calculated.
Previous:As part of asphalt fatigue testing machine equipment? -Huaqiang Electronic Network
Next: UV-1100 spectrophotometric method for rapid measurement of peroxide content of oxides in edible oils - Master's thesis - Dissertation
Related reading
- • [New product broadcast] 1N212 2016-08-10 14:18
- • [New product broadcast] 1N203 2016-08-10 14:18
- • [New product broadcast] 1N202 2016-08-10 14:18
- • [New product broadcast] 1N194A 2016-08-10 14:18
- • [New product broadcast] 1N78C 2016-08-10 14:18